Manufactured

The EasyAir vent is manufactured from extruded aluminium with PVC slide and exterior grade Nylon end caps. Cord controls are available, but are unnecessary where the knob can be easily reached.

Recommended Airflow

Following extensive research in the UK a minimum requirement for background passive ventilation (also known as trickle ventilation) has been adopted. This minimum requirement is for 4000mm2 minimum air opening per average sized room that is used for normal living activities. This does not include bathrooms, laundries or kitchens. These may require more ventilation in the absence of other methods of moisture extraction.

The minimum air opening is proportional to the overall length of the vent x 8000mm2 per metre less an allowance of 740mm2 for end caps.

Example: Vent overall length 600mm = 0.6 x 8000 = 4800 – 740 = 4060mm2

Standard Sizes

OVERALL LENGTH (mm) DAYLIGHT OPENING (mm) MIN AIR OPENING
 
180 158 700mm2
280 258 1500mm2
380 358 2300mm2
480 458 3100mm2
580 558 3900mm2
680 658 4700mm2
780 758 5500mm2
880 858 6300mm2
980 958 7100mm2
1080 1058 7900mm2
1180 1158 8700mm2
1280 1258 9500mm2
1380 1358 10300mm2

Vents exceeding 1100mm in length may require a stiffener if exposed to high wind loadings depending on the depth of the glass pane below the vent. Check when placing your order.

Special Sizes

Special sizes are available on request. Delivery is within three working days of receipt of the order. Prices are based on the nearest standard size above; there is no extra charge for a special size.

Standard sizes can be recut to special requirements by the fabricator. Simply follow the instructions supplied with the vent.

Long Length System

5m lengths and associated components can be purchased subject to certain conditions regarding quantities and training.

Colour Range

Matt black and gloss white powdercoated finishes and silver and bronze anodised finishes are available ex stock. Special anodised or powdercoated colours are available on request.

Dual colour (where the interior colour is different from the exterior colour) is also available.

Price and delivery times are to be established on application.

When Ordering Please Specify

  • Either overall, or daylight (sight) length.
  • Colour (end caps black or white).
  • Right or left hand control (looking from INSIDE).
  • If cords are required – (state length).

Determining Sizes

To determine sizes for vent and glass height, see our Fitting instructions.

Standards and Testing

EasyAir is a high specification vent designed for NZ conditions and complies with NZS 4211 Standard for windows (1985). Its air leakage factor complies with level 2 of the above standard so it can therefore be used commercially in air conditioned buildings. It can be cut to any size within the constraints of appearance (too small) and wind loading (too long).

Easy Air Telarc test reports are available in PDF format. This file is 1.18MB and may take a few minutes to download on slower connections.

We strongly recommend that you read our Frequently asked questions or contact BRANZ for one of their detailed reports appropriate to your application.

Fitting Instructions

For recommended installation procedures, view our Fitting instructions.

Operating Instructions

Read our Operating Instructions and information on how to obtain the maximum benefit from your Easy Air vents.

Pricing

Please contact Joinery Developments for a quote on your requirements. Either call us on 0508 EASY AIR (0508 3279 247) or view our contact page for full contact details.